Web Hosting
We integrate to our web supply the Hosting/Housing service in order to supply a complete and effective service.We are one of the few agencies to have a professional Hosting infrastructure inside.
The decision of building such an infrastructure is owed to our experience in this sector, and to our history in projects, needs, global vision.
web hosting structure able to satisfy the main needs in web: development, service, support.
Our web hosting service is primarily intended for companies and professionals, who need active support and immediate response, but also to those people who are looking for a structure able to provide comlplete support and solutions.
Our hosting plans are configured with the most common applications and utilities: PhP, MySql, Ruby on Rails, Apache. The operating systems ( Linux CentOS) and control panels (Interworx)are installed on redundant cluster with: daily backup, antivirus server, antispam,domain authenticated SMTP various media and utilities among the most common: SSL, Multidomain, Webmail, Web Statistics.
For further informations about our web hosting plans and our networking services, please visit our dedicated website
www.grkhosting.com
Data center notes
The hosting infrastructure is operated from one of the Italy’s leading data centres, Caldera Data Center, in the MIX di Milano campus, the most imprtant Italian interchange Internet, near the data room of several other operators.
The whole surface is covedered by floating floor, easy to be removed for the wiring and the maintenance, and a carrying capacity of over 1000Kg/m2. Under the surface ae located the air ducts for the air conditioning, and the different conduit fot the different wiring types. The power station and the UPS systems are located in a room apart from the data room, and the Diesel emergency engine is located outside the building, in a separate and protected area.
Security and Climate Control
An optimal operating environment is maintained at all times, according to the ETS standards. The temperature in the technical space stays at 21°C (±2°C), with a humidity range of 50% (±10%).
The badge access in all the entrances, the 24x7 security, and the ware recording and handling procedures are warranty of the total control of the peolple and ware entry and exit. The external glass surfaces are all walled, and there is a system of cameras and recording in order to improve the building security. Fire detection and suppression equipment include:
-
VESDA system for the fire detection (Very Early Smoke Detection Alarm), and a smoke and dust detection system: they detect the beginning fire and starts up the extinguishing systems and the fire alarm for the operators.
security.
Sensor network, with a sensor placed every 2 meters.
Each sensor is double: under and on the floor, in order to avoid false alarms.
- Gas FM200 extinguishing system, with 7 single cylinder systems and nozzles all over the ceiling and the floor. Extinguishing power: over 3000m3 and automatic start up. To protect from the water loss and flooding, the room is placed on the first floor, and in the whole building there are no water pipelines.
Power Supply
The power supply is very flexible and reliable, and it’s made of the following plants:
- Self 23.000 V Enel point, in medium voltage 23.000 V, to support the interior lines power on 220V and on -48V
- Redundant processing equipments, for the 220V supply, and the -48V supply, necessary for the telecommunication equipment
- Double UPS 220V system, designe to grant energy until the starting up of the Diesel emergency engine.
- 4 battery, with a 6h authonomy for the -48V supply
- Diesel emergency engine with a 1250KVA Perkins motor, otside the building
All the plants are kept with a continuous maintenance and with constant operation testes.